Overview

OmniVision’s OVMed® OCHTA camera module quadruples the resolution of its predecessor, at 400 x 400, or 160 Kpixels, for clearer images inside the body’s farthest recesses. This module features the CameraCubeChip™ wafer-level technology, enabling it to match the world’s smallest size of its predecessor, at 0.65 mm x 0.65 mm, for deep anatomical access. This technology also allows for the integration of OmniVision’s small size, higher-resolution OH0TA image sensor, along with signal processing and wafer-level optics in a single compact package. With OCHTA camera modules, endoscope, catheter and guidewire OEMs can now develop mass-produced, single-use devices with 1-2 mm optical diameters and higher resolution to address the many challenges posed by reusable equipment, including cross-contamination risks and high maintenance costs.

This ultra-small “chip on tip” camera module features backside illumination (BSI), which provides excellent image quality and better low-light performance to help reduce LED heat and improve sensitivity. Additionally, with OmniVision’s economical CameraCubeChip™ wafer-level packaging technology, the OCHTA makes possible the mass production of high-resolution, single-use medical imaging equipment.

This module’s small size enables devices that can reach deep into the body for neuro, ophthalmic, ENT, cardiac, spinal, urology, gynecology and arthroscopy procedures, as well as dental and veterinary diagnosis and surgery. Furthermore, unlike traditional cameras, all CameraCubeChip™ modules are reflowable, for mounting to a printed circuit board simultaneously with other components using automated surface-mount assembly equipment, increasing quality while reducing assembly costs.

The integrated OH0TA image sensor is built on OmniVision’s PureCel®Plus-S stacked die technology, enabling this module’s increased resolution at 30 frames per second. Additionally, this next-generation pixel technology provides higher color fidelity and excellent low light sensitivity of 3600 mV/lux-sec, along with a high signal-to-noise ratio of 37.5 dB for crisper images. It also offers full well capacity (FWC), zero blooming and 20% lower power consumption of 20 mW for greater patient comfort and longer procedure durations, while reducing noise for crisper images. These images are further improved by the sensor’s exposure and gain control settings, which allow endoscope designers to fine-tune captures—prior to processing—for the best possible video quality under the lighting conditions of specific procedures.

Click here for the press release.

Features

Optical size of 1/31"

Non-autoclavable

Analog output

Single 3.3V power supply

On-chip PLL

Serial peripheral interface (SPI)

Exposure and gain control

Pseudo-global shutter (LED mode)

PureCel®Plus-S pixel structure

Improved sensitivity, FWC, zero blooming, low noise, and low power consumption

Enhanced NIR sensitivity

Square aspect ratio

Minimum package size (total 4 pads)

4 m drive distance

Order Information
Ordering No. Vout(V) Package
Part Specification
SpecOCHTA10-RALA-001A-Z
PackageCameraCubeChip™
TechnologyPureCel®Plus-S
InterfaceSPI
Analog
Shutter TypeRolling Shutter
Resolution400 x 400
CFA (Chroma)Color
Analog / DigitalAnalog
Output FormatAnalog
Operating Temperature-20°C to +70°C
Optical Format1/31"
Frame RateFull @ 30 fps
Pixel Size1.008 µm
Image Area411.264 x 411.264 μm
Package Dimensions650 x 650 x 1198 μm
Product GuidePDF
keyboard_arrow_up